Cabling
Plenum-Rated Cable
Also called: CMP, plenum cable
Cable with a fire-resistant, low-smoke jacket required by code in air-handling plenum spaces — typically the void above a suspended ceiling used for return air.
The requirement exists because a plenum shares air with the occupied space: a burning PVC jacket there distributes toxic smoke building-wide. Plenum-rated CMP is mandatory in those spaces; riser-rated CMR is for vertical shafts between floors, and general-purpose CM for neither.
Using the wrong rating is a failed inspection and a re-pull, not a warning — and it is the fastest way to blow a schedule on an occupied building. Jacket rating is verified against the mechanical drawings before ordering, because 'above the ceiling' does not always mean plenum, and assuming either way is a coin flip.