Skip to main content
Back to Glossary

Security

Request to Exit

Also called: REX, REX sensor

A device — motion sensor, push bar, or button — that signals the access control system of a legitimate exit so leaving does not register as a forced door.

Without REX, every exit through a monitored door raises a door-forced alarm, and operators quickly learn to ignore the alarm queue. REX distinguishes normal egress from an actual breach, which is the only way door alarms stay meaningful.

REX placement and timing need tuning: a sensor with too wide a field releases the door when someone walks past inside, while too short a shunt time alarms on a slow-closing door. These are commissioning settings, adjusted per door after watching real traffic.

Related terms

Access Control
A system that decides electronically who may open which door, when, and records every attempt — replacing mechanical keys with credentials and policy.
Fail-Safe vs Fail-Secure
Two electric lock behaviours on power loss: fail-safe unlocks, fail-secure stays locked. Which is correct depends on egress code and the door's role.
Commissioning
Systematically configuring, testing, tuning, and documenting an installed system so it verifiably performs as designed — the step between installed and working.

More Security terms

Support305 in the press

All press coverage

Need this specified correctly?

Our engineers will review your drawings or quote and tell you exactly where Request to Exit belongs in the design.